12.0Lab Configuration (LAB)


Select the Lab Configuration (LAB) option on the RPMS-EHR Configuration Master Menu to display the following:

Lab Configuration

CVR Days of Lab Results to Retrieve (Cover Sheet)
Select Lab Configuration Option:

12.1Days of Lab Results to Retrieve (Cover Sheet) (CVR)


Select the CVR option on the Lab Configuration menu to display the following:

Days of Lab Results to Retrieve (Cover Sheet)


Duration for Lab Order Display may be set for the following:
100 User USR [choose from NEW PERSON]

200 Location LOC [choose from HOSPITAL LOCATION]

300 Service SRV [choose from SERVICE/SECTION]

400 Division DIV [DEMO INDIAN HOSPITAL]

900 System SYS [DEMO.OKLAHOMA.IHS.GOV]
Enter selection: 900 System DEMO.OKLAHOMA.IHS.GOV
- Setting Duration for Lab Order Display for System: DEMO.OKLAHOMA.IHS.GOV -

Select Inpatient/Outpatient: ??


The number of days back in time to search for lab orders/results. If not

indicated, the default period of 2 days will be used. The maximum number of

days is 100,000 or about 220 years.
Select Inpatient/Outpatient: outpatient Outpatient
Inpatient/Outpatient: Outpatient// Outpatient

Number of Days to Display: 30//

Select Inpatient/Outpatient: Inpatient
Inpatient/Outpatient: Inpatient// Inpatient

Number of Days to Display: 2//

This sets the number of days back in time to display lab orders/results on the Cover Sheet. It can be set for inpatient as well as for outpatient.

13.0Vital Measurement Configuration (VIT)


Select the Vital Measurement Configuration (VIT) option on the RPMS-EHR Configuration Master Menu to display the following:

Vital Measurement Configuration


CVR Measurement Listed on Cover Sheet

OVR Override Default Units

PER Data Entry Permissions

TPL Data Entry Templates


Select Vital Measurement Configuration Option:

The vital signs that appear on the cover sheet and the vital signs that can be entered into the EHR are established on this option.

13.1Measurement Listed on Cover Sheet (CVR)


Select the Measurement Listed on Cover Sheet (CVR) option on the Vital Measurement Configuration menu to display the following:

Measurements Listed on Cover Sheet

Vital signs list for cover sheet may be set for the following:
100 User USR (choose from NEW PERSON)

200 Class CLS (choose from USR CLASS

300 Service SRV (choose from SERVICE/SECTION

400 Location LOC (choose from HOSPTIAL LOCATION)

500 Division DIV (DEMO HOSPITAL)
Enter selection: 500 Division (DEMO HOSPITAL)
Setting vital signs for cover sheet for Division: DEMO HOSPITAL

30

Sequence 30// 30



Are you adding 30 as a new Sequence? Yes// YES
Vital:

The Sequence determines the vital signs that appear on the Cover Sheet and in what order. At the Vital prompt, answer with a BEH MEASUREMENT CONTROL NAME for the sequence.


13.2Override Default Units (OVR)


Select the Override Default Units (OVR) option on the Vital Measurement Configuration menu to display the following:

Override Default Units


Default units for measurement may be set for the following:
100 User USR [choose from NEW PERSON]

200 Class CLS [choose from USR CLASS]

300 Service SRV [choose from SERVICE/SECTION]

400 Location LOC [choose from HOSPITAL LOCATION]

500 Division DIV [DEMO INDIAN HOSPITAL]

900 System SYS [DEMO.OKLAHOMA.IHS.GOV]


Enter selection: 100 User NEW PERSON

Select NEW PERSON NAME: demo DEMO,DOCTOR


-------- Setting Default units for measurement for User: DEMO,DOCTOR --------

Select Measurement Type: temperature

Are you adding TEMPERATURE as a new Measurement Type? Yes// YES
Measurement Type: TEMPERATURE// TEMPERATURE TEMPERATURE

Default Units: ???


Enter a code from the list.
Select one of the following:
0 US

1 METRIC
Default Units:

You use this option to set the default units for a specified measurement type.

13.3Data Entry Permissions (PER)


Select the Data Entry Permissions (PER) option on the Vital Measurement Configuration menu to display the following:

Data Entry Permissions


Can enter vital measurements? may be set for the following:
100 User USR (choose from NEW PERSON)

200 Class CLS (choose from USR CLASS)

300 Service SRV (choose from SERVICE/SECTION)

400 Location LOC (choose from HOSPITAL LOCATION)

500 Division DIV (DEMO HOSPITAL)
Enter selection: 100 User NEW PERSON

Select NEW PERSON NAME: USER,DEMO DU


--------- Setting Can enter vital measurements? for User: USER,DEMO ----------

Can enter vital measurements?: ?


Enter either ā€˜Yā€™ or ā€˜Nā€™.
Can enter vital measurements?: y

This establishes those users and classes who are allowed to enter vital signs.


13.4Data Entry Templates (TPL)


Select the Data Entry Templates (TPL) option on the Vital Measurement Configuration menu to display the following:

Data Entry Templates


Vital Measurement Input Template may be set for the following:
100 User USR (choose from NEW PERSON)

200 Class CLS (choose from USR CLASS)

300 Service SRV (choose from SERVICE/SECTION)

400 Location LOC (choose from HOSPITAL LOCATION)

500 Division DIV (DEMO HOSPITAL)

900 System SYS (DEMO.MEDSPHERE.COM


Enter selection: 100 User NEW PERSON

Select NEW PERSON NAME: ZIPPER,KIMBERLY KZ CLINICAL COORDINATOR


----- Setting Vital Measurement Input Template for User: ZIPPER,KIMBERLY -----

Select Sequence: 1//

Measurement:

The Sequence controls the formatting of the vital measurement data entry dialog. At the Measurement prompt, answer with a BEH MEASUREMENT CONTROL NAME for the sequence.