Documentation of Early and Immediate Functiontm of Nobel Biocare implants; Full arch restorations, fixed bridge



Download 115.34 Kb.
Date conversion09.12.2016
Size115.34 Kb.

May 2007
Documentation of Early and Immediate FunctionTM of Nobel Biocare implants; Full arch restorations, fixed bridge





Author

Year

Implant system

Indication

#
pat.


# impl.

Time of loading

Time of follow-up

CSR %

Aalam et al


2005

Brånemark system Mk III

Complete mandible

16

90

At placement

3 years

96.6

Attard et al

2005

Nobel Biocare, TiUnite

Complete mandible

35

70

After 10 days

1 year

98.6

Balshi & Wolfinger

1997

Brånemark System

Complete mandible

10

40

At placement

4.5 months

80.0

Balshi & Wolfinger

2005

Brånemark System

Complete maxilla

55

522

At placement

1 up to 4 years

99.0

Balshi et al

2005

Brånemark System Machined & TiUnite

Complete mandible & maxilla


51

344

At placement

3 months

98.5

Becker et al

2003

Brånemark System Mk III

Complete mandible

20

92

After 5 days

1 to 4 years

96.3

Bedrossian et al

2006

Brånemark System Zygoma MkIV

Complete maxilla

14

83

Within 2 hours

1 up to 2.5 years

100

Brochu et al

2005

Nobel Biocare, TiUnite

Complete mandible

10

20

Within 10 days

4 months

100

Brånemark et al


1999

Brånemark System
Complete mandible

50

150

At placement

1 year

98

Calandriello et al

2005

Branemark system Mk IV, Replace Select Tapered

Total and partially posterior maxilla

18

60

At placement or within a few days

1 year

96.7

Chow et al

2001a

Brånemark system (machined)

Complete mandible

14

56

At placement

1 year

100

Chow et al

2001b

Brånemark system (machined)

Complete mandible

27

123

At placement

3 - 30 months

98.3

Davo et al

2007

Brånemark System (Zygoma, MkIV)

Complete maxilla

18

104
(36 Z,


68 MkIV)

Within 48 hours

6 – 29 months

97.1

De Bruyn et al

2001

Brånemark System (machined)

Complete mandible

20

60

4-53 days

3 mo - 2 years

90

De Bruyn & Collaert

2002

Brånemark System (machined)

Complete mandible

36

184

0 - 52 days

1 - 2 years

93

Degidi & Piattelli

2003

Frialit 2, Frialoc, IMZ, Brånemark System, Maestro, Restore

All indications

152

646

At placement

2 - 60 months

98.6

Degidi et al

2007

Brånemark System TiU, Ankylos, Frialit-2, Frialoc, IMZ, Maestro, Restore, XiVE

Complete maxilla or mandible

?

133

At placement

4 years

97.7


Engstrand et al

2003

Brånemark System Novum

Complete mandible

95

285

67% at implant placement, the rest 1 - 40 days

1 to 5 years

93.3

Engquist et al
Engquist et al


2004
2005


Brånemark System (MkIII, machined)

Complete mandible

26

104

After 2-3 weeks

1 year
3 years


93

Finne


2007

NobelDirect

All indications, mandible

87

152

At placement

1 year

97.9

Finne et al


2007

NobelDirect, NobelPerfect one-piece

All indications

56

82

At placement

2 years

98.8




Author

Year

Implant system

Indication

#
pat.


# impl.

Time of loading

Time of follow-up

CSR %

Fröberg et al


2006

Brånemark System (machined vs TiUnite)

Complete mandible

15

89
(45 m, 44 T)


Day of surg

18 months

100

Glauser et al

2001A

Brånemark System (MkIV, machined)

All indications

41

127

Within 1 week

1 year

82.7

Glauser et al

2003b

Brånemark System (MkIV, TiUnite)

All indications

38

102

At placement

1 year

97.1

Glauser et al

2005c

Brånemark System (MkIV, TiUnite)

All indications

38

102

At placement

4 years

97.1

Glauser et al

2007d

Brånemark System (MkIV, TiUnite)

All indications

38

102

At placement

5 years

97.1

Hatano

2001

Brånemark System (machined)

Complete mandible

35

105

At placement

2 - 36 months

97.7

Hatano

2003

Brånemark System (machined & TiUnite)

Complete mandible

43

129

At placement

Final, screwretained bridge

97.6

Henry et al

2003

Brånemark System (machined)

Complete mandible

51

153

At placement or within 1 week

1 year

90.7

Horiuchi et al

2000

Brånemark System

Edentulous
Maxillae (5)
Mandibles (12)


14

140
44 max
96 mand


At placement

8 - 24 months

97.2

Jungner et al

2005

Brånemark System (Mk III, machined & TiUnite)

Complete mandible

24

92

After 13 – 62 days

> 5 months

100

Kronström et al

2003

Brånemark System

Complete mandible

17

68

Within 2 - 11 weeks

1 year

93

Malo et al

2003a

Brånemark System (machined)

Complete mandible

44

176

At placement

6 months

96.7
98.2


Malo et al

2005

Brånemark system TiUnite Mk III & Mk IV

Complete maxilla

32

128

Within 3 hours

1 year

97.6

Malo et al

2006

NobelSpeedy (TiUnite)

Complete maxilla & mandible (All-on-4)

46

189

Day of surg

1 year

98.9

Malo et al

2007

NobelSpeedy (TiUnite)

Complete maxilla & mandible (All-on-4)

23

92

Day of surg

1 year

97.8

Maló et al

2007

Brånemark System

All indications

184

433

At placement

5 year

91.0

Olsson et al

2003

Brånemark System (TiUnite)

Complete maxilla

10

61

Within 1-9 days

1 year

93.4

Östman et al

2005

Brånemark system, Replace Select Tapered, TiUnite

Complete maxilla

20

123

Within 12 hours

1 year

99.2

Petersson et al

2001

Brånemark System

Complete mandible

13




Within 3 weeks

5 years

100

Raghoebar et al

2003

Brånemark System (machined)

Complete mandible

40

170

Within 6 weeks

3 years

93

Randow et al
Ericsson et al


1999
2000


Brånemark System

Complete mandible

16
13


88
72


Within 3 weeks

1,5 years
5 years


100
100


Schnitman et al
Schnitman
Schnitman et al


1990
1995
1997


Brånemark System

Complete mandible

10

28

At placement

8 - 10 years

85.7




Author

Year

Implant system

Indication

#
pat.


# impl.

Time of loading

Time of follow-up

CSR %

Tarnow et al

1997

Brånemark System, TiOblast, Astra, Bonefit, ITI, 3i

Complete mandible & maxilla

10

69

At placement

1 - 5 years

97.4

van Steenberghe
et al


2002

Brånemark System (machined)

Complete maxilla

8

61

At placement

1 year

100

van Steenberghe
et al


2004

Brånemark System (Novum)

Complete mandible

50

150

Within 10 days

1 year

92.7

van Steenberghe
et al


2005

Brånemark System Mk III TiUnite

Complete maxilla

27

184

At placement

1 year

100

Villa et al

2005

Brånemark System

Partial or complete mandible

20

97

Within 3 days

1 year

100

Villa et al

2007

Brånemark System

Maxilla, all indications

33

76

At placement

1 year

97.4

Wolfinger et al

2003

Brånemark System

Complete mandible

10 d
24 r


40 d
144 r


At placement

5 years
6 mo's to 4 y'rs


80
96.5




References


  1. Aalam AA, Nowzari H, Krivitsky A. Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: A case series. Clin Impl Dent Rel Res 2005;7:10-16

  2. Attard NJ, David LA, Zarb GA. Immediate loading of implants with mandibular overdentures: One-year clinical results of a prospective study. Int J Prosthodont 2005;18:463-470

  3. Balshi TJ, Wolfinger GJ. Immediate loading of Brånemark implants in edentulous mandibles. A preliminary report. Implant Dent 1997;6:83-88

  4. Balshi SF, Wolfinger GJ, Balshi TJ. A prospective study of immediate functional loading following the Teeth in a day protocol: A case series of 55 consecutive edentulous maxillas. Clin Impl Dent Rel Res 2005;7:24-31

  5. Balshi SF, Allen FD, Wolfinger G, Balshi TJ. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants 2005;20:584-594

  6. Becker W, Becker BE, Huffstetler S. Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: A prospective, open-ended, longitudinal study. J Periodontol 2003;74:695-702

  7. Bedrossian E, Rangert B, Stumpel L, Indresano T. Immediate function with the zygomatic implant: a graftless solution for the patient with mild to advanced atrophy of the maxilla. Int J Oral Maxillofac Implants. 2006 Nov-Dec;21(6):937-42.

  8. Brochu JF, Anderson JD, Zarb GA. The influence of early loading on bony crest height and stability: A pilot study. Int J Prosthodont 2005;18:506-512

  9. Brånemark PI, Engstrand P, Öhrnell LO, Gröndahl K, Nilsson P, Hagberg K, Darle C, Lekholm U. Brånemark Novum. A new treatment concept for rehabilitation of the edentulous mandible preliminary results from a prospective clinical follow-up study. Clin Impl Dent Rel Res 1999;1:2-16

  10. Calandriello R, Tomatis M. Simplified treatment of the atrophic posterior maxilla via immediate/ early function and tilted implants: A prospective 1-year clinical study. Clin Implant Dent Relat Res 2005 ;7:1-12 (Suppl 1)

  11. Chow J, Hui E, Liu J, Li D, Wat P, Li W, Yau YK, Law H. The Hong Kong Bridge Protocol. Immediate loading of mandibular Brånemark fixtures using a fixed provisional prosthesis: preliminary results. Clin Implant Dent Relat Res 2001b;3:166-174 (partly the same material as Chow et al 2001a)

  12. Chow J, Hui E, Li D, Liu J. Immediate loading of Brånemark system fixtures in the mandible with a fixed provisional prosthesis. Appl Osseointegration Res 2001a;2:30-35 (partly the same material as Chow et al 2001 b)

  13. Davo R, Malevez C,Rojas J. Immediate function in atrophic upper jaw using Zygoma implants. J Prosthetic Dent 2007;97 (suppl1):S44-S51

  14. De Bruyn H, Collaert B. Early loading of machined-surface Branemark implants in completely edentulous mandibles: healed bone versus fresh extraction sites. Clin Impl Dent Rel Res 2002; 4:136-42

  15. De Bruyn H, Kisch J, Collaert B, Linden U, Nilner K, Dvarsater L. Fixed mandibular restorations on three early-loaded regular platform Branemark implants. Clin Implant Dent Relat Res 2001;3:176-184

  16. Degidi M, Piattelli A. Immediate functional and non-functional loading of dental implants: a 2- to 60-month follow-up study of 646 titanium implants. J Periodontol 2003;74:225-241

  17. Degidi M, Piattelli A, Iezzi G, Carinci F. Immediately loaded short implants: analysis of a case series of 133 implants. Quintessence Int. 2007 Mar;38(3):193-201.

  18. Engstrand P, Gröndahl K, Öhrnell LO, Nilsson P, Nannmark U, Brånemark PI. Prospective follow-up study of 95 patients with edentulous mandibles treated according to the Brånemark Novum concept. Clin Impl Dent Rel Res 2003;5:3-10

  19. Engquist B, Åstrand P, Anzén B, Dahlgren S, Enquist E, Feldmann H, Karlsson U, Nord PG, Sahlholm S, Svärdström P. Simplified methods of implant treatment in the edentulous lower jaw. Part II: Early loading. Clin Impl Dent Rel Res 2004;6:90-100

  20. Engquist B, Åstrand P, Anzén B, Dahlgren S, Enquist E, Feldmann H, Karlsson U, Nord PG, Sahlholm S, Svärdström P. Simplified methods of implant treatment in the edentulous lower jaw: A 3-year follow-up report of a controlled prospective study of one-stage versus two-stage surgery and early loading. Clin Impl Dent Rel Res 2005;7:95-104 (Continuation of Engquist et al 2004)

  21. Ericsson I, Randow K, Nilner K, Peterson A. Early functional loading of Brånemark dental implants. 5-year clinical follow-up study. Clin Impl Dent Rel Res 2000;2:70-77 (same material as Randow et al 1999 and Petersson et al 2001)

  22. Finne K, Rompen E, Toljanic J. Clinical evaluation of a prospective multi-centre study on one-piece implants. Part 1; Marginal bone level evaluation after 1 year of follow-up. Accepted for publication in International Journal Oral Implantol.

  23. Finne K, Rompen E, Toljanic J. Prospective multicenter study of marginal bone level and soft tissue health of a one-piece implant after 2 years. J Prosthetic Dent 2007;97 (suppl1):S79-S85

  24. Froberg KK, Lindh C, Ericsson I. Immediate loading of Branemark System Implants: a comparison between TiUnite and turned implants placed in the anterior mandible. Clin Implant Dent Relat Res. 2006;8(4):187-97.

  25. Glauser R, Lundgren AK, Gottlow J, Sennerby L, Portmann M, Ruhstaller P, Hammerle CH. Immediate occlusal loading of Brånemark System® TiUnite™ implants placed predominantly in soft bone: 1-year results of a prospective, clinical study. Clin Implant Dent Relat Res 2003b;5 (suppl 1):47-56

  26. Glauser R; Ree A; Lundgren A; Gottlow J; Hammerle CH; Scharer P. Immediate occlusal loading of Branemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res 2001A;3:204-13

  27. Glauser R, Ruhstaller P, Windisch S, Zembic A, Lundgren AK, Gottlow J, Hammerle CH. Immediate occlusal loading of Branemark system® TiUniteTM Implants placed predominantly in soft bone: 4- results of a prospective clinical study. Clin Implant Dent Relat Res 2005c;7(Suppl 1): 52-59 Continuation of Glauser et al 2003.

  28. Glauser R, Zembic A, Ruhstaller P, Windisch S. Five-year results of implants with an oxidized surface placed predominantly in soft bone and subjected to immediate occlusal loading. J Prosthetic Dent 2007d;97 (suppl1):S99-S68

  29. Hatano N. The Maxis new. A novel one-day technique for fixed individualised implant-supported prosthesis in the edentulous mandible using Brånemark system implants. Appl Osseointegration Res 2001;2:40-43

  30. Hatano N, Yamaguchi M, Suwa T, Watanabe K. A modified method of immediate loading using Brånemark implants in edentulous mandible. Odontology 2003;91:37-42

  31. Henry P, van Steenberghe D, Blombäck U, Polizzi G, Rosenberg R, Urgell J P, Wendelhag I. A prospective multicenter study on immediate rehabilitation of edentulous lower jaws according to the Brånemark Novum protocol. Clin Implant Dent Relat Res 2003;5:3:137-142

  32. Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Brånemark System implants following placement in edentulous patients: A clinical report. Int J Oral Maxillofac Implants 2000;15:824-830

  33. Jungner M, Lundqvist P, Lundgren S. Oxidized titanium implants (Nobel Biocare TiUnite) combared with turned titanium implants (Nobel Biocare mark III) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol. Clin Oral Impl Res 2005;16; 3; 308-312

  34. Kronström M, Widbom T, Löfquist L E, Henningson C, Widbom C, Lundberg T. Early functional loading of conical Brånemark implants in the edentulous mandible: A 12-month follow-up clinical report. J Prosthetic Dent 2003;89:335-340

  35. Maló P, Rangert B, Nobre M. “All-on-four” immediate function concept with Brånemark System® implants for completely edentulous mandibles. A retrospective clinical study. Clin Implant Dent Relat Res 2003a;5(Suppl 1):2-9

  36. Maló P, Rangert B, Nobre M. "All-on-Four" immediate-function concept with Branemark System R implants for completely edentulous maxillae: a 1 year retrospective clinical study.Clin Implant Dent Relat Res. 2005;7:88-94 ( Suppl 1)

  37. Maló P, Nobre Mde A, Petersson U, Wigren S. A pilot study of complete edentulous rehabilitation with immediate function using a new implant design: case series. Clin Implant Dent Relat Res. 2006;8(4):223-32.

  38. Maló P, Nobre M, Lopes A. The use of computer-guided flapless implant surgery and 4 implants placed in immediate function to support a fixed denture: Preliminary results after a mean follow-up period of 13 months. J Prosthetic Dent 2007;97 (suppl1):S26-S34

  39. Maló P, Nobre M, Rangert B. Implants placed in immediate function in peridontally compromised sites: A 5-year retrospective and a 1-year prospective study. J Prosthetic Dent 2007;97 (suppl1):S86-S95

  40. Olsson M, Urde G, Andersen E, Sennerby L. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series. Clin Implant Dent Relat Res 2003;5(Suppl 1):81-87

  41. Ostman PO, Hellman M, Sennerby L. Direct implant loading in the edentulous maxilla using a bone density- adapted surgical protocol and primary implant stability criteria for inclusion. Clin Impl Dent Rel Res 2005;7:60-69 (Suppl 1).

  42. Petersson A, Rangert B, Randow K, Ericsson I. Marginal bone resorption at different treatment concepts using Branemark dental implants in anterior mandibles. Clin Implant Dent Relat Res 2001;3:142-147 (same material as Randow et al 1999 and Ericsson et al 2000)

  43. Raghoebar GM, Friberg B, Grunert I, Hobkirk JA, Tepper G, Wendelhag I. 3-year prospective multicenter study on one-stage implant surgery and early loading in the edentulous mandible. Clin Implant Dent Relat Res 2003;5:39-46

  44. Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. Clin Oral Impl Res 1999;10:8-15 (same material as Ericsson et al 2000 and Petersson et al 2001)

  45. Schnitman PA, Wöhrle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997;12:495-503

  46. Schnitman PA, Wöhrle PS, Rubenstein JE. Immediate fixed interim prostheses supported by 2-stage threaded implants. Methodology and results. J Oral Implantol 1990;16:96-105

  47. Schnitman PA. Brånemark implants loaded with fixed provisional prostheses at fixture placement. Nine-year follow-up. J Oral Implantol 1995;21:234

  48. Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches. Ten consecutive case reports with 1-to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324

  49. van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: A clinical report. Int J Oral Maxillofac Implants 2002;17:663-670

  50. van Steenberghe D, Molly L, Jacobs R, Vandekerckhove B, Quirynen M, Naert I. The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: a 1-year follow-up study on 50 consecutive patients. Clin Oral Impl Res 2004;15:360-365

  51. van Steenberghe D,Glauser R, Blomback U, Andersson M, Schutyser, Pettersson A, Wendelhag I. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study. Clin Implant Dent Relat Res. 2005;7(Suppl 1):111-120

  52. Villa R, Rangert B. Early loading of interformainal implants immediately installed after extraction of teeth presenting endodontic and periodontal lesions. Clin Implant Dent Relat Res. 2005;7(Suppl 1):28-35

  53. Villa R, Rangert B. Immediate and early function of implants placed in extraction sockets of maxillary infected teeth: A pilot study. J Prosthetic Dent 2007;97 (suppl1):S96-S108

  54. Wolfinger GJ, Balshi TJ, Rangert B. Immediate functional loading of Brånemark system implants in edentulous mandibles: Clinical report of the results of developmental and simplified protocols. Int J Oral Maxillofac Implants 2003;18:250-257 (continuation of Balshi & Wolfinger 1997)

Please note that abstracts, reviews, case reports, technique descriptions, animal and in vitro tests are excluded. For some articles reporting on several indications, the number of patients/implants per indication is not presented. For these articles, the total number of patients/implants included in the study is presented here.


The database is protected by copyright ©dentisty.org 2016
send message

    Main page